71bu i l di N g A Pr o 64 Ne t w o r k
Digital Copies in Manual Mode
Creating a digital split in Manual Mode follows most of the rules defined for
Auto Mode splits. Any output modules connected in series to an existing
output module can output the same audio as long as the A‑Net Slot range
and A‑Net Receive Port settings are configured properly, and as long as no
input modules installed overwrite the audio. However, the location of the
Pro64 output modules used for the splits will impact the front‑panel transmit
port settings of the input modules.
In the previous example of a stage and front‑of‑house system, adding a
digital copy of the FOH engineer’s inputs for a recording system can be
accomplished by connecting Pro64 output modules to the input module at
front‑of‑house. Unlike Auto Mode, however, this input module needs to be
set to send audio data to its A‑Net Port B in order to make the digital split
work.