29Fr o N t PA N e l Fe A t u r e s
Sample Rate
Pro64 networks can operate at sample rates in three ranges without the use
of sample rate converters. The current network sample rate also determines
the number of available A‑Net Slots.
Sample Rate A-Net Slots Available
1x 44.1/48kHz 64
2x 88.2/96kHz 32
4x 176.4/192k Hz 16
In an all‑analog network, the sample rate can be set at the Control Master to
the following:
44.1kHz•
48• kHz
88.2• kHz
96• kHz
176.4• kHz
192• kHz
When an external clock is used with a Pro64 digital I/O device, the system can
lock to any sample rate within a range that is ±10% of the currently displayed
sample rate.
Pro64 Series Supported Sample Rates
Sample Rate Minimum Maximum
1x 44.1/48kHz 39.7kHz 52kHz
2x 88.2/96kHz 79.4kHz 104kHz
4x 176.4/192k Hz 158.8kHz 208kHz
Changing the Sample Rate
The network sample rate can be changed only at the Control Master.
Changing the sample rate is done with the selection button found below the
Sample Rate LED readout.
To choose a new sample rate, press the selection button beneath the sample
rate list. Pressing the button selects the next sample rate in the list and
immediately starts blinking the new rate’s LED and the Enter/Cancel LED;
confirmation is required. To confirm the new sample rate, press the En t E r
button. To exit without changing the sample rate, press Ca n C E l .