86bu ild i N g A Pr o 64 Ne t w o r k
Digital Copies in Manual Mode
Creating a digital split in Manual Mode follows most of the rules defined for
Auto Mode splits. Any output modules connected in series to an existing
output module can output the same audio as long as the A‑Net Slot range
and A‑Net Receive Port settings are configured properly, and as long as no
input modules installed overwrite the audio. However, the location of the
Pro64 output modules used for the splits will impact the front‑panel transmit
port settings of the input modules.
Example 8: Adding a digital split of the FOH signals
B A
B A
Input
B A
Output
B A
Input
B A
Output
B A
Input
B A
Input
B A
Output
1 2
Merger
3 4 5 6 7 8 9 10
B A
B A
Input
B A
Output
B A
Input
B A
Output
B A
Input
B A
Input
B A
Output
1 2
Merger
3 4 5 6 7 8 9 10
B A
B A
Input
B A
Output
B A
Input
B A
Output
B A
Input
B A
Input
B A
Output
1 2
Merger
3 4 5 6 7 8 9 10
B A
B A
Input
B A
Output
B A
Input
B A
Output
B A
Input
B A
Input
B A
Output
1 2
Merger
3 4 5 6 7 8 9 10
STAGE
FRONT OF HOUSE
RECORDING
B A
B A
Input
B A
Output
B A
Input
B A
Output
B A
Input
B A
Input
B A
Output
1 2
Merger
3 4 5 6 7 8 9 10
The input module at FOH transmits its audio data out of both A-Net ports,
providing a digital split.
In the previous example of a stage and frontof‑house system, adding a
Page view 95